Voltage Sensors

We are a leading Manufacturer of lv 25-p/sp2 voltage transducer, lv 25-p, evolution board and lv 20p voltage transducer from New Delhi, India.

LV 25-P/SP2 Voltage Transducer

LV 25-P/SP2 Voltage Transducer
  • LV 25-P/SP2 Voltage Transducer
Get Best Quote
Approx. Price: Rs 3,750 / PieceGet Latest Price

Product Details:

Minimum Order Quantity5 Piece
Ambient Operating Temperature-40 to +85 Degree C
Ambient Storage Temperature-45 to+90 Degree C
Mass22g
Primary Nominal RMS Current10mA
Primary Current Measuring Range0 to +/-14 mA
Conversion Ratio2500 Ratio 1000
Frequency50 Hz
BrandLem

Features :
  • Closed loop current transducer using the Hall effect
  • Insulating plastic case.

Principal of uses:

  • For voltage measurements, a current proportional to the measured voltage must be passed through an external rsistor R, which is selected by the user and installed in series with the primary circuit of the transducer.

Advantages:

  • Excellent accuracy
  • Very good linearity
  • Low thermal drift
  • Low response time
  • High bandwidth
  • High immunity to external interference
  • Low disturbance in common mode.

Application:

  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery supplied applications
  • Uninterruptible Power Supplies (UPS)
  • Power supplies for welding applications.
Request
Callback


Additional Information:

  • Item Code: VP-SENV-0002
  • Pay Mode Terms: Other
  • Port of Dispatch: courier
  • Production Capacity: 1000
  • Delivery Time: immediatly else 2-3 weeks
Send Bulk Enquiry
View PDF

LV 25-P

LV 25-P
  • LV 25-P
Get Best Quote
Approx. Price: Rs 3,350 / PieceGet Latest Price

Product Details:

Minimum Order Quantity5 Piece
Primary Nominal RMS Current10mA
Primary Current Measuring Range0~+/-14mA
Conversion Ratio2500 Ratio 1000
Secondary Nominal RMS Current25mA
Ambient Operating Temperature0 to 70 Degree C

Features:
  • Closed loop current transducer using the Hall effect
  • Insulating plastic case.

Principal of uses:

  • For voltage measurements, a current proportional to the measured voltage must be passed through an external rsistor R, which is selected by the user and installed in series with the primary circuit of the transducer.

Advantages:

  • Excellent accuracy
  • Very good linearity
  • Low thermal drift
  • Low response time
  • High bandwidth
  • High immunity to external interference
  • Low disturbance in common mode.

Application:

  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery supplied applications
  • Uninterruptible Power Supplies (UPS)
  • Power supplies for welding applications.
Request
Callback


Additional Information:

  • Item Code: VP-SENV-0001
  • Pay Mode Terms: Other
  • Port of Dispatch: courier
  • Production Capacity: 1000
  • Delivery Time: immediatly else 2-3 weeks
Send Bulk Enquiry
View PDF

Evolution Board

Evolution Board
  • Evolution Board
Get Best Quote
Approx. Price: Rs 550 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Temperature Range-40 to +85 Degree C
Ambient Storage Temperature-45 to+90 Degree C
Frequency50/60Hz
Power SourceElectric

Evolution Board for Voltage Sensors LV25-P, LV25-P/SP2
Request
Callback


Additional Information:

  • Item Code: VP-EB-0001
  • Pay Mode Terms: Other
  • Port of Dispatch: courier
  • Production Capacity: 1000
  • Delivery Time: immediatly else 1 week
Send Bulk Enquiry

LV 20P Voltage Transducer

LV 20P Voltage Transducer
  • LV 20P Voltage Transducer
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity5 Piece
Ambient Operating Temperature0 to 70 Degree C
Ambient Storage Temperature-25 to 85 Degree C
Conversion Ratio2500 Ratio 1000
Frequency50Hz

Features:
  • Closed loop (compensated) voltage transducer using the Hall effect
  • Insulated plastic case recognized according to UL 94-V0
  • Optimized.

Principle of use:
  • For voltage measurements, a current proportional to the measured voltage must be passed through an external resistor R 1 which is selected by the user and installed in series with the primary circuit of the transducer.

Advantages:
  • Excellent accuracy
  • Very good linearity
  • Low thermal drift
  • Low response time
  • High bandwidth
  • High immunity to external interference
  • Low disturbance in common mode.

Applications:
  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery supplied applications
  • Uninterruptible Power Supplies (UPS)
  • Power supplies for welding applications .
Request
Callback


Additional Information:

  • Item Code: VP-SENV-0003
  • Pay Mode Terms: Other
  • Port of Dispatch: courier
  • Production Capacity: 1000
  • Delivery Time: immediatly else 2-3 weeks
Send Bulk Enquiry
View PDF
X

Explore more products



Reach Us
Upender Gupta (Proprietor)
No. 53, Friends Enclave, East Block
Sultanpuri, New Delhi- 110086, Delhi, India



Call Us

Share Us

F GT L


Send E-mailSend SMS